Challenge

Large pumps are expensive to prototype and test, so the design had to be verified against its duty point before manufacture, and any hydraulic losses identified early.

Approach

A full 3D model of the impeller and volute with rotating and stationary domains coupled through interfaces, and a performance curve built from several flow rates around the design point.

Key Findings

  • The design met its required duty point, confirming the hydraulic sizing.
  • Losses concentrated near the volute tongue and in non-uniform flow leaving the impeller.
  • Flow uniformity at the impeller outlet was the main lever for further efficiency gains.

Deliverables

Head and efficiency predictions, pressure and velocity maps, and design verification ahead of physical testing. See our article on optimizing pump design through CFD simulation and validation.